Measuring Method of Pretreatment Solution For Enamel

Measuring Method of Pretreatment Solution For Enamel

  • Categories:Company news
  • Author:
  • Origin:
  • Time of issue:2022-01-07
  • Views:0

(Summary description)The surface pretreatment of the enamel metal body needs to be done before coating, which can improve the bonding degree (adhesion strength)

Measuring Method of Pretreatment Solution For Enamel

(Summary description)The surface pretreatment of the enamel metal body needs to be done before coating, which can improve the bonding degree (adhesion strength)

  • Categories:Company news
  • Author:
  • Origin:
  • Time of issue:2022-01-07
  • Views:0
Information

The surface pretreatment of the enamel metal body needs to be done before coating, which can improve the bonding degree (adhesion strength) of the metal body and the enamel frit, reduce the defects of enamel products such as pinholes, bubbles, etc., thereby greatly saving Various costs of enamel manufacturers.

The methods of metal surface pretreatment for enamel are usually: sandblasting, air firing (thermal degreasing) method, chemical cleaning method, the process of chemical cleaning method generally includes chemical degreasing, pickling and neutralization. Today, we will focus on the metal surface treatment. The measurement method of the solution, remember to collect it, it will definitely help you.

 

1. Concentration determination of degreasing solution

1.10mL sample, drop 3 drops of phenolphthalein solution, shake and mix well, the solution will appear pink;

2 Take 1% H2SO4 test solution and slowly drop it into the beaker until the color of the phenolphthalein solution turns white;

3. The volume of the consumed H2SO4 test solution divided by 5 is the percentage of the total alkali content of the degreasing solution. ,

2. Determination of sulfuric acid concentration

1. Take a sample of 100 mL of the solution to be tested, cool it to room temperature, use a pipette to take 10 mL and place it in a 400 mL beaker, add 100 mL of distilled water, and add sulfuric acid concentration identification indicator, which is red at this time;

2. Dissolve 54g of anhydrous sodium carbonate (NaCO3) in 1000mL of pure water as the titration test solution;

3. Drop the titration test solution until the solution changes from red to orange;

4. At this time, the consumption of the titration test solution is the percentage of the sulfuric acid concentration of the sample solution, that is, nml NaOH(aq)=n% H2SO4.

three. Determination of Ferrous Sulfate Concentration

1. Use a straw to take 100mL of pickling solution and pour it into a 400mL beaker, add 200mL of distilled water, and then add 10mL of concentrated sulfuric acid. At this time, the color of the liquid in the beaker is white;

2. Dissolve 10.5g potassium permanganate (KMnO4) in 1000mL pure water as the titration test solution;

3. Drop the titration test solution until the solution turns from white to light pink;

4. At this time, every 1mL of the test solution titrated is equal to 0.5% of the iron content of the sample (nmL KMnO4(aq)=0.5n% Fe; 1% Fe is equivalent to 2.72% FeSO4.)

Fourth, the determination of the neutralization solution

1. Use a pipette to take 100mL of neutralization solution and pour it into a 400mL beaker;

2. Take 0.1g of methyl red and dissolve it in 100mL of ethanol as a neutralization indicator solution;

3. Put 3~5 drops in the beaker and stir evenly, at this time the color is orange;

4. Titrate with 0.5% hydrochloric acid until the solution turns from orange to red;

5. At this time, the consumption of the titration test solution is the percentage of the sodium oxide (Na2O) concentration of the measured neutralization solution;

Note: The standard concentration of sodium oxide (Na2O) in the neutralization solution is 0.2%~0.4%; the new neutralization solution does not need to be measured within 1 to 2 days of normal operations.